Supplied By: Hettich Benelux, Nederlands

CABINET HOUSING AND SYSTEMS:
Hettich Benelux Article number 8800.0000
Cabinet size external D x W x H in mm 1355 x 910 x 2025
Cabinet size internal D x W x H in mm 950 x 690 x 1460 (1500 without baseplate)
Internal volume in liters 973
Internal construction Stainless steel 304, RAL 9016 coated
Exterior construction Galvanised steel, RAL 9016 coated
Floor space in m² 1.01
Wall isolation/thickness in mm 55, Glass 21 mm - 2.8 W/m²K
Castors 4 swivel castors with adjustable foot
Water drain in floor connection 1/2“ external thread
Lockable door Yes
Transit port location and size In the back wall, 27 mm
Fresh air inlet Adjustable, in the back wall
Humidity system (optional) Ultrasonic, ambient to 90%; ± 3%, temp. depending
Humidity sensor (optional) Capacitive
CO2 system (optional) Up to 10,000 ppm adjustable
Airflow system Horizontal, through the back pressure wall to the front
Visual alarm notifiction At front panel, red - green LED lights
SHELVES:
Maximum tiers of shelves 15
Number of standard delivered shelves 5
Max. load per shelf in kg 50
Shelf size (W x D) in mm 630 x 900
Growth area per shelf in m2 0.57
Max. total growth area in m2 (15 shelves) 8.5
Minumum clearance between shelves in mm 44
Shelf material Perforated stainless steel 304
LIGHT SYSTEM:
Light intensity 100-125 μmol.m-2.s-1, measured at a 90° angle at a distance of about 25 cm
Light dimmable Between 10% and 100%
Light colour / spectrum White, spectrum is 95% sunlight compatible
COOLING SYSTEM:
Type of cooling system Top mounted aircooled system
Refrigerant R134a
Refrigerant in kg 0.28
GWP-value 1430
CO2 equivalent per 1000 kg 400
SPECIFICATIONS:
Environmental temperature in °C 15-25
Temperature range lights on °C 10-45
Temperature range lights off °C 4-45
Temperature homogeneity lights on, including (optional) humidity in °C ± 1.5
Temperature homogeneity lights off in °C ± 1.0
Temperature adjustable in °C per 0.1
Airflow speed in m/s <0.2
Noise level in dB(A) <45
ELECTRICAL AND SUPPLIES:
Deionised water supply for humidier (optional) <5μS/cm; 1/4“ internal thread; 0,5 - 6 Bar
Electrical supply 230V, AC, ± 10%, 50/60Hz
Potentional free alarm contact At the back wall
Type controller Dicon
LAN connection Web based interface, at the back wall, CAT 6
TRANSPORT:
Unit weight (excluding shelves) in kg ± 295
Shelf weight in kg 5
Cabinet and wooden crate in kg 310
Dimensions transport crate D x W x H in mm 1430 x 1200 x 2250